Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 61(22): 7881-7905, 2016 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-27779120

RESUMO

Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring patient treatments. Focused on this goal of translation into clinical operation, we systematically addressed remaining challenges and questions. We developed a robust energy calibration routine and corresponding quality assurance protocols. Furthermore, with dedicated experiments, we determined the positioning precision of the system to 1.1 mm (2σ). For the first time, we demonstrated the application of the slit camera, which was intentionally developed for pencil beam scanning, to double scattered proton beams. Systematic experiments with increasing complexity were performed. It was possible to visualize proton range shifts of 2-5 mm with the camera system in phantom experiments in passive scattered fields. Moreover, prompt γ-ray profiles for single iso-energy layers were acquired by synchronizing time resolved measurements to the rotation of the range modulator wheel of the treatment system. Thus, a mapping of the acquired profiles to different anatomical regions along the beam path is feasible and additional information on the source of potential range shifts can be obtained. With the work presented here, we show that an application of the slit camera in clinical treatments is possible and of potential benefit.


Assuntos
Câmaras gama , Raios gama , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Radiometria/instrumentação , Radioterapia Assistida por Computador/instrumentação , Humanos
2.
Phys Med Biol ; 61(6): 2432-56, 2016 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-26943881

RESUMO

Proton therapy is an advantageous treatment modality compared to conventional radiotherapy. In contrast to photons, charged particles have a finite range and can thus spare organs at risk. Additionally, the increased ionization density in the so-called Bragg peak close to the particle range can be utilized for maximum dose deposition in the tumour volume. Unfortunately, the accuracy of the therapy can be affected by range uncertainties, which have to be covered by additional safety margins around the treatment volume. A real-time range and dose verification is therefore highly desired and would be key to exploit the major advantages of proton therapy. Prompt gamma rays, produced in nuclear reactions between projectile and target nuclei, can be used to measure the proton's range. The prompt gamma-ray timing (PGT) method aims at obtaining this information by determining the gamma-ray emission time along the proton path using a conventional time-of-flight detector setup. First tests at a clinical accelerator have shown the feasibility to observe range shifts of about 5 mm at clinically relevant doses. However, PGT spectra are smeared out by the bunch time spread. Additionally, accelerator related proton bunch drifts against the radio frequency have been detected, preventing a potential range verification. At OncoRay, first experiments using a proton bunch monitor (PBM) at a clinical pencil beam have been conducted. Elastic proton scattering at a hydrogen-containing foil could be utilized to create a coincident proton-proton signal in two identical PBMs. The selection of coincident events helped to suppress uncorrelated background. The PBM setup was used as time reference for a PGT detector to correct for potential bunch drifts. Furthermore, the corrected PGT data were used to image an inhomogeneous phantom. In a further systematic measurement campaign, the bunch time spread and the proton transmission rate were measured for several beam energies between 69 and 225 MeV as well as for variable momentum limiting slit openings. We conclude that the usage of a PBM increases the robustness of the PGT method in clinical conditions and that the obtained data will help to create reliable range verification procedures in clinical routine.


Assuntos
Raios gama , Fótons , Terapia com Prótons/métodos , Prótons , Doses de Radiação , Humanos , Imagens de Fantasmas , Terapia com Prótons/efeitos adversos
3.
Phys Med Biol ; 60(10): 4197-207, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25955576

RESUMO

Irradiation with protons and light ions offers new possibilities for tumor therapy but has a strong need for novel imaging modalities for treatment verification. The development of new detector systems, which can provide an in vivo range assessment or dosimetry, requires an accurate knowledge of the secondary radiation field and reliable Monte Carlo simulations. This paper presents multiple measurements to characterize the prompt γ-ray emissions during proton irradiation and benchmarks the latest Geant4 code against the experimental findings. Within the scope of this work, the total photon yield for different target materials, the energy spectra as well as the γ-ray depth profile were assessed. Experiments were performed at the superconducting AGOR cyclotron at KVI-CART, University of Groningen. Properties of the γ-ray emissions were experimentally determined. The prompt γ-ray emissions were measured utilizing a conventional HPGe detector system (Clover) and quantitatively compared to simulations. With the selected physics list QGSP_BIC_HP, Geant4 strongly overestimates the photon yield in most cases, sometimes up to 50%. The shape of the spectrum and qualitative occurrence of discrete γ lines is reproduced accurately. A sliced phantom was designed to determine the depth profile of the photons. The position of the distal fall-off in the simulations agrees with the measurements, albeit the peak height is also overestimated. Hence, Geant4 simulations of prompt γ-ray emissions from irradiation with protons are currently far less reliable as compared to simulations of the electromagnetic processes. Deviations from experimental findings were observed and quantified. Although there has been a constant improvement of Geant4 in the hadronic sector, there is still a gap to close.


Assuntos
Algoritmos , Raios gama , Terapia com Prótons/métodos , Prótons , Ciclotrons , Imagens de Fantasmas , Fótons , Radiometria/métodos
4.
Trans Am Ophthalmol Soc ; 111: 24-33, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24072944

RESUMO

PURPOSE: To test the validity and reliability of a new tool for assessing residents' competence in ophthalmic surgery. Changing paradigms of ophthalmic education in the United States have influenced worldwide ophthalmic education and necessitated new methods of assessing resident competence. Accordingly, a new tool for assessing residents' competence in ophthalmic surgery (phacoemulsification) that could be applicable internationally was developed. We hypothesize that this instrument is valid and reliable. METHODS: A panel of six international content experts adapted a previously published tool for assessing phacoemulsification. The tool (called the International Council of Ophthalmology's Ophthalmology Surgical Competency Assessment Rubric, or ICO-OSCAR:phaco) was reviewed by 12 international content experts for their constructive comments, which were incorporated to ensure content validity. Ten expert cataract surgery teachers then graded six recorded phacoemulsification surgeries with the ICO-OSCAR:phaco to investigate inter-rater reliability. RESULTS: The coefficient alpha statistic (a measure of reliability/internal consistency) for the ICO-OSCAR:phaco as a whole was 0.92, and 17 of its 20 dimensions had alpha coefficients greater than 0.70. CONCLUSIONS: The ICO-OSCAR:phaco is a valid and reliable assessment tool that could be applied internationally to satisfy the global need of new instruments to comply with emerging trends in ophthalmic education. A toolbox of similar surgical competency assessment tools is being developed.


Assuntos
Competência Clínica/normas , Educação de Pós-Graduação em Medicina/normas , Internato e Residência/normas , Procedimentos Cirúrgicos Oftalmológicos/educação , Avaliação Educacional/normas , Humanos , Facoemulsificação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...